A practice that owns an X-ray machine is a radiation employer under the Ionising Radiations Regulations 2017, with legal duties that sit alongside its veterinary ones and are enforced by the Health and Safety Executive. This guide sets out what those duties are for a practice taking radiographs: registering with HSE, the radiation protection adviser and supervisor, risk assessment, controlled areas and local rules, dose limits and monitoring, equipment testing, and the records to keep.

The short version

Register with HSE before using an X-ray set. Appoint a radiation protection adviser (RPA) in writing and consult them on the matters the regulations list. Carry out a radiation risk assessment, designate the X-ray room or working zone as a controlled area where the assessment says so, write local rules for it and name a radiation protection supervisor (RPS) in them. Keep every person’s dose as low as reasonably practicable and below the legal limits, train staff and record the training, have the installation critically examined and the safety features tested, and keep the records for the periods the regulations set.

This guide follows the regulations for Great Britain. Northern Ireland has its own Ionising Radiations Regulations (Northern Ireland) 2017; check the local version before relying on the detail below.

Registering with HSE

The regulations use three tiers, scaled to risk: notification, registration and consent. HSE’s guidance puts X-ray devices used by vets in the registration tier. Consent, the top tier, is needed for listed higher-risk practices, and one of them is giving radioactive substances to animals for veterinary diagnosis or treatment by injection, ingestion or inhalation. A consent involves a safety assessment and an inspection, can take up to three months, and HSE says the average charge is expected to be up to £6,000.

Applications go through HSE’s online service. After that:

  • there is no renewal, but you must tell HSE straight away if you stop the work or make a material change, such as a change of employer name;
  • HSE can revoke a registration, for example after serious breaches or a false declaration.

Risk assessment and restricting exposure

Before starting any new work with ionising radiation, the employer must assess the risk to employees and anyone else, identify every hazard that could lead to a radiation accident and evaluate how serious the risks are. Practices with five or more employees must record their general risk assessment under the Management of Health and Safety at Work Regulations, and HSE notes that it should cover radiation.

The regulations then set an order of controls:

  1. engineering controls, design features, safety features and warning devices;
  2. systems of work;
  3. personal protective equipment, such as lead aprons, where it reduces exposure further.

The employer must also set dose constraints at the planning stage where appropriate, and fix an investigation level: any employee whose effective dose passes 15 mSv in a calendar year, or a lower figure the employer chooses and writes into the local rules, triggers an investigation. If the assessment shows an accident is reasonably foreseeable, a contingency plan is required and summarised in the local rules.

The RPA and the RPS

Radiation protection adviserRadiation protection supervisor
WhoAn individual or body meeting HSE’s competence criteria, with experience relevant to your workUsually an employee involved in the radiography, with authority over those doing it
How appointedIn writing, stating the scope of adviceNamed in the local rules
RoleAdvises on compliance; must be consulted on designated areas, plans and acceptance into service of new or modified equipment, calibration of monitoring equipment, and periodic testing of safety features and systems of workSupervises day-to-day compliance with the local rules
ResponsibilityAdvisory; the employer stays liableSupervisory; the employer stays liable

HSE’s code of practice adds that holding a competence certificate does not by itself make an RPA suitable for a particular type of work, and that the RPS needs training, time and resources for the role.

Controlled areas and local rules

An area must be designated controlled where people need to follow special procedures to restrict significant exposure, or where anyone working there is likely to receive more than 6 mSv a year effective dose, 15 mSv to the lens of the eye, or 150 mSv to the skin or extremities. A supervised area applies at lower thresholds (1 mSv, 5 mSv and 50 mSv) or where conditions need watching.

A controlled area needs warning signs and must be physically marked out where reasonably practicable. HSE’s code of practice accepts that this may not be practicable for veterinary radiography, in which case the operator must be able to see anyone near the area and switch the X-ray set off quickly from the normal operating position.

Only classified persons, or other people entering under written arrangements, may be in a controlled area. Local rules are required for every controlled area and must at least contain:

  • the dose investigation level;
  • a summary of any contingency arrangements;
  • the names of the RPSs;
  • a description of the area and its designation;
  • the working instructions, including the written arrangements for non-classified staff.

HSE advises keeping them short, specific to the room and true to actual practice, displayed where people work.

Dose limits and monitoring

PersonEffective doseLens of the eyeSkinHands and feet
Employees and trainees 18 and over20 mSv20 mSv500 mSv500 mSv
Trainees under 186 mSv15 mSv150 mSv150 mSv
Anyone else, including clients1 mSv15 mSv50 mSv50 mSv

All figures are per calendar year. Exceeding a limit is an offence.

Employees likely to receive more than 6 mSv a year, 15 mSv to the eye or 150 mSv to skin or extremities must be designated classified persons. They must be 18 or over and certified fit, and their doses must be assessed and recorded by an approved dosimetry service. Most practice staff will not be classified, but if they enter a controlled area under written arrangements, the practice must be able to show, with dosemeters or another suitable form of measurement, that their doses stay below the classification thresholds.

Designated areas also need monitoring, with equipment tested before first use and periodically by a suitably qualified person.

For pregnant staff, once the employer has been told in writing, the dose to the foetus must be as low as reasonably practicable and unlikely to exceed 1 mSv for the rest of the pregnancy. Female staff must be told about this risk and the reasons to notify early.

A suspected overexposure must be investigated immediately and, unless it is ruled out beyond reasonable doubt, reported to HSE and the person affected.

Equipment testing

  • On installation. Whoever installs the set, new or second-hand, must carry out a critical examination of the installation, checking that safety features and warning devices work and that shielding is adequate, and must consult an RPA on its scope and results.
  • In service. The practice must keep engineering controls, safety features and warning devices properly maintained, with thorough examinations and tests at suitable intervals. The regulations set no interval; the programme is one of the matters the RPA must be consulted on.
  • Protective equipment. Lead aprons, gloves and similar equipment must be examined at suitable intervals and kept in good repair.

Training

Everyone working with radiation needs radiation protection training and enough information to understand the risks and precautions. Staff working in a controlled area need specific training on that room. Training must be repeated at appropriate intervals and documented.

Records to keep

RecordMinimum retention
Area monitoring results and monitoring equipment tests2 years
Personal dose measurements for non-classified staff entering a controlled area2 years
Report of an immediate overexposure investigation2 years
Analysis after a contingency plan has been used2 years
Dose records for classified persons (held by the dosimetry service)Until the person is or would be 75, and at least 30 years
Full overexposure investigation and dose assessmentUntil the person is or would be 75, and at least 30 years
Training givenDocumented; the regulations set no period

Keep the registration certificate, RPA appointment, risk assessment and local rules together with the records above. If the practice still runs a wet-film processor, the developer and fixer are hazardous waste with their own codes; our clinical waste guide covers waste classification.

FAQ

Common questions

Does a veterinary X-ray machine need to be registered with HSE?

Yes. HSE lists X-ray devices used by vets among the radiation generators that need a registration before use. Administering radioactive substances to animals, for example in nuclear medicine, needs a separate consent, which involves a safety assessment and an inspection. You apply online, and a registration does not need renewing unless you stop the work or make a material change.

Do vets and nurses who take radiographs need personal dosemeters?

The regulations do not say so in those words. Staff likely to exceed 6 mSv a year must be classified and monitored through an approved dosimetry service. Non-classified staff may only enter a controlled area under written arrangements, and the practice must be able to show, with personal dosemeters or another suitable form of measurement, that their doses stay low enough. Ask your RPA which method fits your set-up.

Who can be the radiation protection supervisor in a practice?

Usually an employee who is close to the radiography work, such as a senior vet or nurse. HSE's code of practice says the RPS should know the regulations and local rules, have enough authority over the people doing the work, understand the precautions, have time to do the job and know what to do in an emergency. The RPS must be named in the local rules.

How often must a veterinary X-ray machine be tested?

The regulations set no fixed interval. The installer must carry out a critical examination when the set is installed, including second-hand equipment. After that, the practice must maintain safety features and warning devices and have them thoroughly examined and tested at suitable intervals, consulting its RPA on the programme. Monitoring equipment must be tested before first use and at appropriate intervals.

Can a pregnant member of staff carry on taking radiographs?

The regulations set a dose condition rather than a ban. Once the employee has told her employer in writing, the employer must keep the dose to the foetus as low as reasonably practicable and unlikely to exceed 1 mSv for the rest of the pregnancy. Female staff working with radiation must be told about this risk and the importance of notifying early. Review the risk assessment with your RPA when notified.

Related reading: The RCVS Practice Standards Scheme explained for UK practices, Clinical waste disposal rules for UK veterinary practices, more on regulation, all guides.

Leave work at five. Not seven.

Tell us about your clinic and we’ll show you VaroVet, with your records moved across from your current system.